Click to enlarge image
|
Specifications
| Frequency |
1.6~30KHz |
Full solid-state design
|
MOS-FET Power amplifier |
Multi-power module combine
|
HSS-3000S (3W) : 4 Modules |
| HSS-5000S (5KW) : 6Modules |
Remote control service
|
Mimic control panel |
| RS232 422/485 |
- Output impedance : 50ohm
- Frequency range : 3∼27.5MHz
- Pre set channel : 12CH or 128CH
- Type of emission CW, SSB, AM, Data (RTTY, ARQ, NBDP, DSC, Fax with external modem)
- Audio input level : -20dBm to +10dBm (adjustable)
- Frequency stability : within 1 x 10-8/day
- Harmonics and spurious : -55dB or less than
- Tuning time : 3 Seconds max
- Carrier suppression : less than -54dB
- Inter modulation distortion : less than -25dB
- Audio frequency response : less than -6dB (300 to 2700Hz)
- Hum and Noise : less than-50dB (Suppression Carrier SSB Mode)
- Power requirements : 220V/380V.AC 50/60Hz 3 Phase
- Ambient temperature : -5°C to +50°C
- Humidity : less than 95% at 40°C
- Dimension : 1160(W) x 2000(H) x 900(D)
Feature
- This solid type equipment is designed with only semi-conductors, consumes low electric power, thus, we can operate it at low operation cost with easy and simple maintenance in safety.
- Complete Module Construction. Each module is separate in draw type compartment sliding forward for easier investigation on parts.
- Total output is made with aggregated combination of 4modules (HSS-3000S) and 6modules (HSS-5000S). therefore, even in case of failure in some of modules, it operates steadily at steadily lower output power
Functions
- It is equipped with circuit elimination hums and noise while compensation distorted waves. Thus it proves good quality transmission
- It is easy to set wave bands for 12CH or 128CH, and output levels are adjustable by channel.
- Output level is controlled by CPU to make accurate adjustment and to prevent mechanical parts from wears by smooth turning.
- All functions for remote control operation are built-in. Therefore, if it is installed optional Remote control unit, remote control operation is possible by Modem.
- It has 4-step protection circuits from over-temperature and thunders.
- Every unit has individual protection circuits. And it is easy to do maintenance works, as LED shows green for normal condition and red for abnormal condition.
- It has smoke and over-temperature sensors, which make power-off automatically if they sense such environment.
- Cooling fan is operating when transmitting and it is off when idle to save power cost and enhance parts life.
- Output efficiency monitoring and protection functions are equipped in order to avoid malfunction coming from mistake in control by operator.
- It has Keying protection function in case of trouble in transmitting.
- it has surge protection against over-voltage and over-current.
|
|
|
|
| |
|
|
|